The CO₂ 40 g cartridge, also known as SPARKLET CARTOUCHE, is designed for pressurizing a 6 L or 9 L compatible portable shower. It enables rinsing water to be propelled when the shower is activated, to ensure rapid intervention in the event of hazardous product splashes, contamination or burns.
This consumable is essential for the proper operation of the portable shower. It must be replaced after each use, or as part of the periodic maintenance of the equipment, with a recommended replacement every 6 months.
A replacement cartridge for 6 L or 9 L portable showers
Providing a spare SPARKLET CARTRIDGE CO₂ 40 g enables the shower to be quickly put back into service after triggering, inspection or maintenance. This is an important point for workshops, laboratories, industrial areas, first-aid stations or intervention vehicles where the equipment must remain available at all times.
Technical data
| Technical specifications - CO₂ cartridge for portable shower 6 L or 9 L |
| Designation |
Sparklet cartridge CO₂ 40 g |
| Product type |
Gas cartridge for portable shower |
| Gas |
CO₂ |
| Capacity |
40 g |
| Compatibility |
6 L and 9 L compatible portable showers |
| Use |
Pressurizing and restarting the portable shower |
| Packaging |
Single unit |
| Approximate dimensions |
H 200 x Ø 150 mm |
| Approximate weight |
200 g |
| Recommended replacement |
After each use or every 6 months |
When is a spare cartridge required?
A spare cartridge is recommended for sites where the portable shower must remain immediately available: first-aid stations, workshops, laboratories, storage areas, industrial environments or emergency vehicles. It prevents a used or controlled shower from remaining not available for lack of replacement consumables.
FAQ - Sparklet cartridge CO₂ 40 g for 6 L or 9 L portable showers
Is this cartridge suitable for 6 L and 9 L portable showers?
Yes, this cartridge is intended for compatible 6 L or 9 L portable showers. Before ordering, we still recommend checking the shower part number or the instructions in the equipment manual.
Why do I need to replace the cartridge after use?
Once the portable shower has been activated, the cartridge should no longer be considered available for further use. Replacing the cartridge ensures that the equipment is correctly pressurized again.
Why schedule periodic replacement every 6 months?
Periodic replacement ensures the availability of the portable shower and prevents first-aid equipment remaining in service with a cartridge that is too old or not sufficiently reliable.
When should I check the condition of the cartridge?
The condition of the cartridge should be checked during periodic inspections of the portable shower, after every use and before putting it back into service. It is also important to ensure that the cartridge is correctly stored, undamaged and suitable for the equipment concerned.