Click for more products.
No products were found.
2-AKRON®

2-AKRON®

Founded in the United States in 1918, Akron Brass is a historic brand in the firefighting equipment industry. Now part of the IDEX Fire & Safety group, it is particularly known for its firefighting monitors, handheld nozzles, spray heads, and water flow control systems.

The manufacturer develops solutions for fire and rescue services as well as for industrial applications and onboard equipment. Its expertise encompasses manual, motorized, and remote-controlled spray equipment for water or foam operations, depending on the configuration.

At MMF Protection et Sécurité, we offer a selection of Akron Brassfirefighting monitors , handheld nozzles, water/foam nozzles, and accessories, as well as a wide range of genuine replacement parts. As an official Akron Brass distributor and authorized repair center, we assist you with the selection, maintenance, and repair of your professional equipment.

Handheld nozzle AKRON TurboJet 1720

€1,394.06 (tax excl.)
€1,394.06 (tax excl.)

FM Approved

The Akron Brass Turbojet 1720 handheld handheld nozzle is a high-performance, versatile solution designed for firefighting professionals. Available in France exclusively at MMF Protection et Sécurité, this handheld nozzle provides optimal jet control and great adaptability to a variety of emergency situations.

Handheld nozzle AKRON TurboJet 1744 (without handle)

Reference: 38179
€1,177.37 (tax excl.)
€1,177.37 (tax excl.)

The Turbojet 1744 handheld firehandheld nozzle r is an adjustable-flow fire handheld nozzle r designed for operations requiring power, precision, and rapid adjustment of the water stream. It allows users to select from multiple flow rates, switch from a straight stream to a fan spray with a simple twist, and features a Pyrolite body that combines lightness with durability. Suitable for urban and industrial fires as well as demanding operations, it offers effective stream control to ensure the safety of firefighters.

Handheld nozzle AKRON TurboJet 1766 (without handle)

Reference: 39374
€1,142.81 (tax excl.)
€1,142.81 (tax excl.)

The Turbojet 1766 is a handheld nozzle with constant flow (flow remains the same whatever the shape of the jet) and several flow settings for greater control. It can be fitted with an ergonomic pistol-grip handle and a top opening/closing handle.

Akron Brass location - Ohio USA
Akron Brass location - Ohio USA

Fire Monitors for a Wide Range of Firefighting Applications

A fire monitor installed on a fire apparatus faces different operational requirements than a portable monitor or a fixed industrial fire protection system. Available water flow, range of motion, control options, and installation conditions all play an important role in selecting the right equipment.

Manual and Portable Fire Monitors

The Apollo, Mercury, and Omega monitor families cover a variety of applications, from rapid deployment at emergency scenes to fixed fire protection installations.

Portable monitors provide a flexible way to deliver high-volume water streams where they are needed, provided that the available water supply and anchoring arrangements are appropriate. Fixed and apparatus-mounted monitors are designed for applications requiring a permanent or vehicle-integrated firefighting solution.

We help customers identify suitable configurations based on flow requirements, inlet and outlet connections, monitor stability, and horizontal and vertical operating ranges.

Electric Fire Monitors and Remote-Controlled Systems

The StreamMaster II, DeckMaster, and FireFox monitor families offer electric operation for fire apparatus and installations where remote control provides an operational advantage.

Depending on the model and configuration, Akron Brass electric monitors can incorporate wired or wireless controls, CAN-based control systems, and programmable positioning functions. The StreamMaster II, for example, features absolute position sensors that support programmable obstacle avoidance, oscillation, and stow/deploy positions.

These capabilities are particularly useful when a monitor is installed in an elevated position, integrated into a fire apparatus, or operated in an area where personnel need to maintain a safer distance from potential hazards.

For fire apparatus manufacturers, OEMs, system integrators, and industrial operators, we can help evaluate monitor specifications and control options to determine their suitability for the intended installation.

Akron Brass Master Stream Nozzles: Matching Stream Performance to the Application

The nozzle is a critical component of any fire monitor. It determines the stream pattern, hydraulic performance, and, depending on its design, the ability to apply water or foam effectively.

Our selection includes Akron Brass master stream nozzles from the Akromatic, AkroFoam, and Mercury product families.

Akromatic nozzles are designed to provide automatic flow regulation over specified operating ranges, with manual or electric pattern control depending on the model. Certain configurations are suitable for high-flow monitors and applications requiring remote adjustment between straight stream and fog patterns.

For foam applications, Akron Brass offers specialized equipment, including the AkroFoam family of self-educting master stream foam nozzles. Selecting the appropriate configuration requires careful consideration of the foam concentrate, operating flow and pressure, and compatibility with the overall foam application system.

We can assist you in selecting a master stream nozzle based on your existing monitor, required flow rate, available operating pressure, and desired stream pattern. Mechanical and hydraulic compatibility must always be verified to ensure proper operation.

Akron Brass Handline Nozzles for Firefighters and Emergency Response Teams

Akron Brass also develops a comprehensive range of handline nozzles designed to meet the demands of professional firefighting operations, offering different approaches to flow control and stream pattern adjustment.

Our product selection includes models from the Turbojet, Assault, and UltraJet families, with various configurations available depending on the application.

Turbojet nozzles feature selectable gallonage settings, allowing firefighters to adjust water flow to changing conditions. Assault nozzles use a fixed-orifice design to provide consistent flow characteristics at their rated operating pressure. UltraJet nozzles combine smooth bore stream performance with the ability to switch to narrow or wide fog patterns.

Selecting the right handline nozzle involves more than choosing a rated flow. Available pressure and water supply, hose diameter, inlet connection, and the operating practices of the firefighting team must also be considered.

We help our customers select nozzle configurations that are compatible with their existing hose lines and operational requirements.

Akron Brass Equipment for Industrial Fire Protection

Akron Brass monitors and nozzles are also used in industrial fire protection applications where large-volume water streams, remote operation, or coverage of exposed areas may be required.

Petrochemical facilities, energy installations, ports, storage terminals, and waste processing plants can present demanding operating conditions. Important considerations include stream reach, available flow rates, corrosion exposure, installation constraints, and operator safety.

For these applications, we can help assess requirements for manual or electric monitors, master stream nozzles, and associated control systems. Our approach is to identify equipment configurations suited to the site's fire protection needs, available water supply, and operating conditions.

We work with industrial fire protection teams, engineering companies, and system integrators on Akron Brass equipment requirements for projects in France and international markets.

MMF: An Authorized Akron Brass Repair Center

Fire monitors are designed for demanding service conditions, but long-term operation can lead to wear or mechanical and electrical issues. Rotation and elevation mechanisms, seals, drive components, and control systems may require inspection, servicing, or replacement over time.

As an authorized Akron Brass repair center, we provide equipment inspection, troubleshooting, maintenance, and repair services at our workshop.

Fire Monitor Repair and Refurbishment

We service manual and electric fire monitors, identifying the causes of operating problems such as restricted rotation, excessive mechanical play, elevation issues, leaks, or electric control malfunctions.

Depending on the equipment model and its condition, our technicians can replace worn or damaged components and restore the operation of the affected mechanisms.

Repair and refurbishment can extend the service life of existing equipment and provide an alternative to complete replacement, subject to the overall condition of the monitor and the availability of replacement parts.

Genuine Akron Brass Replacement Parts and Service Kits

We maintain an inventory of genuine Akron Brass replacement parts to support the maintenance and repair of the manufacturer's firefighting equipment.

Our range includes seals, gears, worm gears, rotation and elevation components, motors, actuators, electronic components, and service kits.

These parts cover different generations of equipment, including StreamMaster, DeckMaster, and Apollo monitors, as well as various master stream and handline nozzle models.

To identify the correct replacement part or service kit, we recommend providing the exact equipment model and, whenever possible, its serial number. For certain products, the manufacturing date or mechanism version may also be needed to confirm compatibility.

Looking for an Akron Brass fire monitor, nozzle, replacement part, or repair solution? Our team can assist you with equipment selection, maintenance, and refurbishment. Contact MMF Protection et Sécurité to discuss your requirements and receive a technical recommendation or quotation.

To help you identify the components of your AKRON product, you can also refer to our technical drawings and Akron Brass documentation.

Play Video

Menu

Settings